Water Treatment

Water treatment is, collectively, the industrial-scale processes that makes water more acceptable for an end-use, which may be drinking, industry, or medicine. Water treatment is unlike small-scale water sterilization that campers and other people in wilderness areas practice. Water treatment should remove existing water contaminants or so reduce their concentration that their water becomes fit for its desired end-use, which may be safely returning used water to the environment.



Nano Molecular Technology

Salt-Free Conditioner with CATALYTIC MEDIA

      The technologically advanced Salt less Anti-Scale CATALYTIC MEDIA is an innovative solution that prevents all of the negative effects of calcium and magnesium, while allowing the positive health benefits to remain. The system is maintenance free, chemical free, salt free and does not require costly regeneration and backwashing. It does not add nor remove anything from the water. It leaves the water in its own natural state with all the benefits of naturally soft water.

The Principle

      The principal behind our saltless anti-scale media is quite simple. The saltless anti-scale media acts as a catalyst by accelerating the transformation of the calcium and magnesium minerals into harmless “Nano” particles. When the inlet water goes into the water conditioner tank, the salt free scale control media which then acts as a catalyst and pulls the hardness minerals of calcium and magnesium and then transforms these calcium and magnesium minerals into inactive Nano crystal particles. when the crystals reach a size in the range of nano-meters (one billionth the size of a meter) they detach and are carried away by the water flow. These Nanoscopic particles make their way through plumbing systems without attaching on to pipes, fixtures, valves, or heating elements. An important secondary benefit is that the existing scale in pipes and equipment is also dissolved over time. The manganese and calcium already built up on the walls of pipes and equipment will slowly dissolve and in just a few short months mineral build up will be eliminated

Saltless Anti-Scale Media

SUITABLE FOR

      Apartments, hospitals, Hotels, small houses, Hostels, bungalows, villas etc.

Technical data of the CATALYTIC MEDIA?

      Surface: Molecular. Matrix: Polyacryl. Size: 0.4 - 1.2 mm. Color: Light yellow. Bulk density: 50 lbs. per cu. ft.

Operating conditions

      Contact time with water 5 seconds, pH range 6-9, chlorine less than 3 ppm, iron (Fe), hydrogen sulphide (H2S), oil and grease must be removed prior CATALYTIC MEDIA conditioner. Max. temperature up to 150° F however the maximum temperature is governed by media tank and other components used in a system. The CATALYTIC MEDIA is not limited to the water hardness therefore we can design system to any level of hardness. For best performance it is recommended that the media "rest" for 8 hours per day. This is never a problem in residential installation. In commercial applications running 24 hours a day two systems should be used alternating each 8 hours shift. Hardness level difference

      If the water is tested after the CATALYTIC MEDIA System is installed the hardness level will remain the same as a test for “total hardness” in actuality is a test for the presence of calcium and magnesium minerals which are retained in the water. The test can sometimes even test slightly higher due to the existing scale being removed from the plumbing (This is usually seen more on the hot water side do to more hardness build up on in the hot water heater and pipes). After the existing scale is removed the hardness will go back to normal hardness level. TDS reduction depends of the original TDS value.

You can enjoy all these benefits:

Guaranteed Scale control and Prevention
Reduced Hard Water Spotting on Your Dishes, Mirrors & Bathtubs
Perfect for Places Where Salt-based Softeners are Undesired
Feel the difference of softer skin and smoother hair after every shower.
Conditioned Water without the Slippery Feel
Use 50% Less Detergents, Clothes become softer, cleaner, and brighter
Increase Efficiency of Water Heater & Save Energy Expenses
Increase Lifespan for Pipes and Home Appliances like dishwashers, water heaters, and laundry equipment
Easy to install, No Electricity
Maintenance Free, No Salt require, No regeneration/reactivation
WQA Tested & Certified to NSF/ANSI-61 Quality Standards.

Hardness level different

      If the water is tested after the CATALYTIC MEDIA System is installed the hardness level will remain the same as a test for “total hardness” in actuality is a test for the presence of calcium and magnesium minerals which are retained in the water. The test can sometimes even test slightly higher due to the existing scale being removed from the plumbing (This is usually seen more on the hot water side do to more hardness build up on in the hot water heater and pipes). After the existing scale is removed the hardness will go back to normal hardness level. TDS reduction depends of the original TDS value. We had TDS reduction between 10-20%.

Is the CATALYTIC MEDIA certified?

      The CATALYTIC MEDIA meets the stringent European water quality standards, which include the DVGW-W512 guidelines. The German test method DVGW-W512 was developed for the evaluation of the efficiency of water treatment installations for reducing lime scale build-up.